AGA Electricity Supply
Most AGAs require an electricity supply, some just a 13amp socket, others a 32amp 'Cooker Circuit', there's a list of the requirements below however we can provide a more detailed specification after carrying out a home survey.
Fuel / Model | 2 Oven | 3 Oven | 4 Oven | 5 Oven |
Gas Conventional Flue AGA (excluding Dual Control) |
||||
Non-AIMS No Module |
None required when no AIMS and no Module | n/a | ||
With AIMS | 13amp switched socket | n/a | ||
With Module | 32amp cooker circuit | n/a | ||
AIMS & Module | 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket | n/a | ||
Gas Powered Flue AGA (excluding Dual Control) |
||||
No Module | All power flue AGAs (with or without AIMS) require 13amp socket for the flue fan | n/a | ||
With AIMS | Uses same supply from 13amp socket | n/a | ||
With Module | 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket | n/a | ||
AIMS & Module | 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket | n/a | ||
Electric Economy 7 AGA (also known as '30amp Electric AGA') |
||||
Three oven and AIMS not available | 32amp cooker circuit (on all the time) Plus a 6amp 'signal'/trigger circuit which is on only during 'Economy 7' times |
n/a | ||
With Module | A second (two in total) 32amp cooker circuit | n/a | ||
Electric 13amp AGA |
||||
With or without AIMS No Module |
13amp switched fused spur point (2.5kW load) |
n/a | ||
With Module | An additional 32amp cooker circuit It is NOT possible to plug the 13amp AGA in to the socket on a combined cooker control with socket |
n/a | ||
AGA 7 Series eR7 (and Total Control) |
||||
No Module | n/a | 32amp cooker circuit | n/a | 32amp cooker circuit +13amp socket |
With Module | n/a | A second (two in total) 32amp cooker circuit | n/a | A second (two in total) 32amp cooker circuit +13amp socket |
AGA 7 Series R7 (Dual Control) |
||||
No Module | n/a | 32amp cooker circuit | n/a | 32amp cooker circuit +13amp socket |
With Module | n/a | A second (two in total) 32amp cooker circuit | n/a | A second (two in total) 32amp cooker circuit +13amp socket |
AGA R3 Series Cookers |
||||
R3 100-4h (Twin hotplate) |
TWO 13amp switched, fused spur connection units (don't fit 13amp sockets - the cable will not fit in a plug top!) | n/a | ||
R3 100-4i (Hotplate plus Induction) |
TWO 13amp switched, fused spur connection units (don't fit 13amp sockets - the cable will not fit in a plug top!) | n/a | ||
AGA eR3 Series Cookers |
||||
eR3 100-3, 100-4 and 110-4 (non-induction) |
32amp cooker circuit | n/a | ||
eR3 100-3i, 100-4i and 110i (with induction) |
32amp cooker circuit and a 13amp socket outlet |
n/a | ||
eR3 150-4, 160-5 and 170-5 (non-induction) |
32amp cooker circuit and a 13amp socket outlet |
n/a | ||
eR3 150-4i, 160-5i and 170-5i (with induction) |
32amp cooker circuit and TWO 13amp socket outlets |
n/a | ||
AGA 60 (All-Electric or Dual Fuel Model) |
||||
32amp cooker circuit | n/a | n/a | ||
Oil Fired AGA |
||||
No Module | 13amp socket | n/a | 13amp socket outlet | n/a |
With Module | 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket | n/a | 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket | n/a |
2-Zone Ceramic Electric or Gas Hob for Four Oven AGA |
||||
2-Zone gas or electric ceramic hob (4 oven only) | 13amp socket outlet to left of AGA | n/a | ||
Induction hob (5 Oven 7 Series [Dual/Total Control] only) | n/a | Nothing extra - fed from existing Warming Cupboard socket | ||
AGA Freestanding Module |
||||
Gas or electric ceramic hob version | 32amp cooker circuit | n/a | ||
AGA Six-Four Cooker |
||||
Gas hob version | 32amp cooker circuit (6.6kW) | n/a | ||
Electric ceramic hob version | 45amp cooker circuit which MUST be wired using 10 sq mm cable (16.9kW) | n/a | ||
AGA Masterchef XL 110 |
||||
Dual Fuel (gas hob / electric ovens) | 32amp cooker circuit (12kW) | n/a | ||
With Induction hob | 45amp cooker circuit (17kW) | n/a | ||
AGA Masterchef XL 90 |
||||
Dual Fuel (gas hob / electric ovens) | 32amp cooker circuit (8.6kW) | n/a | ||
With Induction hob | 45amp cooker circuit (16kW) | n/a |